Skip to main content
Welcome to the University of Lethbridge
  • Library
  • Directory
  • Intranet
  • MyExperience
  • Webmail
  • Bridge
  • Moodle
Study here Give
Facilities: Building Maintenance
Close
  • About
  • Services
    • Building Maintenance Operation
    • Architectual Commissioning
    • Carpentry
    • Distribution of Goods
    • Door & Lock Systems
    • Event Set-ups
    • Furniture Replacement
    • Paint Shop
    • Sign Shop
  • Resources
    • Health & Safety Manuals
    • Design & Construction Standards
  • Contact
    • Profiles
    • Urgent Work Requests
    • Work Requests
  • Library
  • Directory
  • Intranet
  • MyExperience
  • Webmail
  • Bridge
  • Moodle
Study here Give
Resources
  • Health & Safety Manuals
    • Safe Work Procedures
      • Carpenter Shop
        • Glass or Mirror Cutting
        • Wood, Metal, Plastic Cutting
      • Locksmith Shop
        • Door Installation
        • Glass Removal & Replacement
        • Glass or Mirror Cutting
        • Window Installation
      • Paint Shop
        • Airless Sprayer
        • Furniture Finishing
        • Patching
        • Wood, Metal, Plastic Cutting
      • Sign Shop
        • Sign Hanging
      • Appendix A
        • Bandsaw
        • Chop Saw
        • Circular Table Saw
        • Cleaning Solvents & Flammables
        • Compressed Air
        • Compressed Gas Cylinders
        • Defective Tools
        • Disk Sander
        • Drill Press
        • Electrical Extension Cords
        • Electrical Safety
        • Explosive/Powder Actuated Fastening Tools
        • Fire & Fire Extinguishers
        • Flammable & Toxic Materials
        • Forklift Operation
        • Grinding
        • Hand Held Power Circular Saw
        • Hand Held Power Tools
        • Hand Powered Lifts, Roustabouts & Hyjacks
        • Hantavirus
        • Housekeeping
        • Insect Repellents
        • Jointer
        • Metal Scaffolds
        • Mobile Aerial Work Platform
        • Mosquitoes/West Nile Virus
        • Non-Powered Hand Tools
        • Overhead Doors
        • Oxygen-Acetylene or Oxygen-Propane Torch
        • Personal Headphones
        • Portable Arc Welder
        • Portable Grinders
        • Portable Ladders
        • Power Washer
        • Propane
        • Proper Lifting Techniques
        • Reporting Rattlesnakes
        • Rotating Emergency Flashing Warning
        • Shaper/Router
        • Step Ladders
        • Tiger Torches
        • Welding, Cutting & Burning
    • Download Full Manuals
  • Design & Construction Standards
    • Performance Requirements
      • Substructure Performance
      • Shell Performance
      • Interior Performance
    • Life Cycle Activities
      • Commissioning
      • Facility Maintenance
    • Existing Conditions
      • Concrete
      • Thermal/Moisture
      • Openings
      • Specialty Doors/Frames
      • Finishes
      • Specialties
      • Information Specialties
      • Interior Specialties
      • Equipment
      • Furnishings
      • Conveying Equipment
      • Fire Suppression
      • Plumbing
      • Sanitary Sewerage
      • Plumbing Fixtures
      • Heating/Ventilating/Air-Conditioning

Equipment

Educational and Scientific Equipment

Laboratory Equipment

  1. Specific requirements for laboratory exhaust systems shall be reviewed with the University Safety and Risk Management Department and the University Project Manager. ANSI/AIHA Z9.5-2003 American National Standard for Laboratory Ventilation and NFPA-45 Standard on Fire Protection for Laboratories Using Chemicals shall be followed.
  2. Design of fume hood exhaust systems should be in accordance with CSA Standard Z316, latest edition and the Minimum Guidelines for Laboratory Fume Hoods (PWGSC). Testing of fume hood performance as it pertains to installation and lab design shall follow ANSI/ASHRAE 110-1995 Method of Testing Performance of Laboratory Fume Hoods.
  3. All systems shall have adequate supply of make-up air tempered to room temperature.
  4. All spaces shall be designed under negative pressure to the adjacent spaces and as per Table 23 06 00.
  5. Provide a duct washdown system for all perchloric acid exhaust systems. Perchloric duct system must be dedicated.
  6. Use Type 316 stainless steel ducts.
  7. Provide a face velocity monitor on all fume hoods.
  8. All laboratory hoods and safety cabinets shall be equipped with visual and audible alarms to warn laboratory workers of unsafe air flows (Alnor 335).
  9. Provide an eye wash station in laboratories that have at least one fume hood. Design should be in accordance with ANSI A358.1-2004 Emergency Eyewash and Shower Equipment.
  10. Where corrosive material is used in the laboratory, locate eyewash station within 3 metres of material.

Students

  • Academic calendar
  • Student Enrolment and Registrar Services
  • Student opportunities
  • Student services
  • Study here

Information for

  • Alumni
  • Donors
  • Visitors and community

Campus

  • Careers at uLethbridge
  • Events
  • Faculty and staff intranet
  • Maps and tours
  • News
Visit the University of Lethbridge Homepage
  • Lethbridge, Alberta, Canada
  • Contact us
  • Calgary Campus
  • Faculty and staff directory

The University is located on traditional Blackfoot Confederacy territory. We honour the Blackfoot people and their traditional ways of knowing in caring for this land, as well as all Aboriginal peoples who have helped shape and continue to strengthen our University community.

©2025 University of Lethbridge | Terms of use